Energy saving factors affecting analysis on district heating system with distributed variable frequency speed pumps

点击次数:

论文类型:期刊论文

发表时间:2017-07-05

发表刊物:APPLIED THERMAL ENGINEERING

收录刊物:SCIE、EI、Scopus

卷号:121

页面范围:779-790

ISSN号:1359-4311

关键字:District heating; Distributed variable-frequency speed pumps; Energy-saving; Factors affecting

摘要:The distributed variable-frequency speed pump (DVFSP) district heating system is not only to set circulating pump in the heat source, but also to set booster pumps in the heating pipeline network. All pumps adopt frequency conversion control. Compared with the traditional centralized power heat supply system, the distributed variable-frequency speed pump district heating system has more advantages in solving the hydraulic imbalances and improving the energy-saving rate of the heating system. In China the application of distributed variable speed pumps in the district heating (DH) network has been considered as a technology improvement that has a potential of saving energy, compared to the conventional central circulating pump (CCCP) DH system. In order to analyze the factors affecting energy-saving rates and pipe network balance mathematical analytical method is used in this paper. In the conclusion, how to further improve the energy saving rate will be put forward together with the improvements for hydraulic stability balance as a reference of optimized engineering design. (C) 2017 Elsevier Ltd. All rights reserved.