location: Current position: Home >> Scientific Research >> Paper Publications

Using silver nanocluster/graphene nanocomposite to enhance photoelectrochemical activity of CdS:Mn/TiO2 for highly sensitive signal-on immunoassay

Hits:

Indexed by:期刊论文

First Author:Song, Jie

Correspondence Author:Wu, S (reprint author), Dalian Univ Technol, Sch Chem, Dalian 116023, Peoples R China.

Co-author:Wang, Jiamian,Wang, Xiuyun,Zhao, Wei,Zhao, Yanqiu,Wu, Shuo,Gao, Zhanming,Yuan, Jingli,Meng, Changgong

Date of Publication:2016-06-15

Journal:BIOSENSORS & BIOELECTRONICS

Included Journals:SCIE、EI、PubMed

Volume:80

Page Number:614-620

ISSN No.:0956-5663

Key Words:Silver nanocluster and graphene nanocomposite; Photoelectrochemical immunoassay; Signal-on; Enhanced photo-to-current conversion efficiency; CdS:Mn/TiO2

Abstract:A highly sensitive signal-on photoelectrochemical (PEC) immunosensor was fabricated here using CdS:Mn/TiO2 as photoelectrochemical sensing platform, and silver nanoclusters and graphene naocomposites (AgNCs-GR) as signal amplification tags. The immunosensor was constructed based on the specific sandwich immunoreaction, and the photo-to-current conversion efficiency of the isolated protein modified CdS:Mn/TiO2 matrix was improved based on the synergistic effect of AgNCs-GR. Under irradiation, the photogenerated electrons from the AgNCs at a higher conduction band edge level could be transport to the CdS:Mn/TiO2 matrix with the assistance of highly conductive graphene nanosheets, as well as recycle the trapped excitons in the defects-rich CdS:Mn/TiO2 interface. The electron transport and exciton recycle reduced the possibility of electron-hole recombination and greatly improved the photo-to-current conversion efficiency of the sensing matrix. Based on the signal enhancement, a signal-on PEC immunosensors was fabricated for the detection of carcinoembryonic antigen (CEA), a model analyte related to many malignant diseases. Under optimal conditions, the as-prepared immunosensor showed excellent analytical performance, with a wide linear range from 1.0 pg/mL to 100 ng/mL and a low limit of detection of 1.0 pg/mL. The signal-on mode provided 2.48 times higher sensitivity compared with signal-off mode. This strategy demonstrated good accuracy and high selectivity for practical sample analysis, thus may have great application prospective in the prediction and early diagnosis of diseases. (C) 2016 Elsevier B.V. All rights reserved.

Pre One:An ATMND/SGI based label-free and fluorescence ratiometric aptasensor for rapid and highly sensitive detection of cocaine in biofluids

Next One:三苯胺功能染料的合成及在谷胱甘肽超低电位光电检测中的应用