Quantification of ondansetron, granisetron and tropisetron in goat plasma using hydrophilic interaction liquid chromatography-solid phase extraction coupled with hydrophilic interaction liquid chromatography-triple quadrupole tandem mass spectrom

点击次数:

论文类型:期刊论文

发表时间:2018-09-15

发表刊物:JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES

收录刊物:PubMed、SCIE

卷号:1095

页面范围:50-58

ISSN号:1570-0232

关键字:Ondansetron; Granisetron; Tropisetron; HILIC-SPE; HILIC-MS/MS; Plasma

摘要:An assay method to quantify ondansetron (OND), granisetron (GRA) and tropisetron (TRO) in goat plasma has been successfully developed and validated. This method procedure for the analysis of OND, GRA and TRO was involved of extracting samples with hydrophilic interaction liquid chromatography (HILIC) solid phase extraction (SPE) and determination by liquid chromatography coupled to tandem mass spectroscopy. An SPE method for the simultaneous extraction of OND, GRA and TRO with high efficiency and selectivity was developed. Prior to HPLC-MS/MS analysis, most of the sources of interference present in the supernatant after protein precipitation of plasma proteins was efficiently removed from the samples by the HILIC SPE treatment. For the quantification of OND, GRA and TRO in the samples, tandem mass spectrometry operating in positive electrospray ionization mode with multiple reaction monitoring was used. The calibration curve was performed in the range of 0.2-20 ng/mL for the target OND, GRA and TRO in goat plasma samples. The precision of the intra- and inter-day assay for OND, GRA and TRO were 1.84-6.23% and 3.89-5.31%, 2.63-6.29% and 3.76-5.31%, 1.99-5.67% and 2.64-4.70%, respectively. The accuracy of the intra- and inter-day assay for OND, GRA and TRO were 89.15-97.39% and 89.46-95.17%, 91.08-400.82% and 91.24-99.47%, 92.30-100.74% and 94.21-97.90%, respectively. For the determination of OND, GRA and TRO in plasma samples, no significant matrix effects were observed. The mean absolute recoveries were 103-150%, 115-121%, and 98-141% for OND, GRA and TRO, respectively. Furthermore, the mean process efficiency values of silica SPE were 98-135%, 92-124%, and 72-109% for OND, GRA and TRO, respectively.