吴硕
Personal Homepage
Paper Publications
Using silver nanocluster/graphene nanocomposite to enhance photoelectrochemical activity of CdS:Mn/TiO2 for highly sensitive signal-on immunoassay
Hits:

Indexed by:期刊论文

First Author:Song, Jie

Correspondence Author:Wu, S (reprint author), Dalian Univ Technol, Sch Chem, Dalian 116023, Peoples R China.

Co-author:Wang, Jiamian,Wang, Xiuyun,Zhao, Wei,Zhao, Yanqiu,Wu, Shuo,Gao, Zhanming,Yuan, Jingli,Meng, Changgong

Date of Publication:2016-06-15

Journal:BIOSENSORS & BIOELECTRONICS

Included Journals:SCIE、EI、PubMed

Volume:80

Page Number:614-620

ISSN No.:0956-5663

Key Words:Silver nanocluster and graphene nanocomposite; Photoelectrochemical immunoassay; Signal-on; Enhanced photo-to-current conversion efficiency; CdS:Mn/TiO2

Abstract:A highly sensitive signal-on photoelectrochemical (PEC) immunosensor was fabricated here using CdS:Mn/TiO2 as photoelectrochemical sensing platform, and silver nanoclusters and graphene naocomposites (AgNCs-GR) as signal amplification tags. The immunosensor was constructed based on the specific sandwich immunoreaction, and the photo-to-current conversion efficiency of the isolated protein modified CdS:Mn/TiO2 matrix was improved based on the synergistic effect of AgNCs-GR. Under irradiation, the photogenerated electrons from the AgNCs at a higher conduction band edge level could be transport to the CdS:Mn/TiO2 matrix with the assistance of highly conductive graphene nanosheets, as well as recycle the trapped excitons in the defects-rich CdS:Mn/TiO2 interface. The electron transport and exciton recycle reduced the possibility of electron-hole recombination and greatly improved the photo-to-current conversion efficiency of the sensing matrix. Based on the signal enhancement, a signal-on PEC immunosensors was fabricated for the detection of carcinoembryonic antigen (CEA), a model analyte related to many malignant diseases. Under optimal conditions, the as-prepared immunosensor showed excellent analytical performance, with a wide linear range from 1.0 pg/mL to 100 ng/mL and a low limit of detection of 1.0 pg/mL. The signal-on mode provided 2.48 times higher sensitivity compared with signal-off mode. This strategy demonstrated good accuracy and high selectivity for practical sample analysis, thus may have great application prospective in the prediction and early diagnosis of diseases. (C) 2016 Elsevier B.V. All rights reserved.

Personal information

Professor
Supervisor of Doctorate Candidates
Supervisor of Master's Candidates

Main positions:化学学院副院长

Other Post:辽宁省教学名师,宝钢优秀教师特等奖提名奖,中国分析测试学会青年学术委员会委员

Gender:Female

Alma Mater:南京大学

Degree:Doctoral Degree

School/Department:化学学院

Discipline:Analytical Chemistry. Biochemistry and Molecular Biolog

Business Address:化工综合楼C305

Click:

Open time:..

The Last Update Time:..


Address: No.2 Linggong Road, Ganjingzi District, Dalian City, Liaoning Province, P.R.C., 116024