Professor
Supervisor of Doctorate Candidates
Supervisor of Master's Candidates
Open time:..
The Last Update Time:..
Indexed by:会议论文
Date of Publication:2010-06-20
Included Journals:EI、Scopus
Volume:1
Page Number:1207-1212
Abstract:Full scale tests were conducted on a monopod structure before and after an icebreaking cone was added. The effectiveness of mitigating ice induced vibration through adding ice-breaking cone was evaluated based on test data. It was found that significant ice induced vibration can occur on both of vertical and conical structures, but that vertical structures suffer from more intense and harmful steady state vibration. The dynamic ice force and structure response of vertical and conical structure were discussed based on test data. Copyright ? 2010 by The International Society of Offshore and Polar Engineers (ISOPE).