Analysis of a ground source heat pump system using an unsaturated 3-dimensional model

点击次数:

论文类型:期刊论文

发表时间:2017-02-05

发表刊物:APPLIED THERMAL ENGINEERING

收录刊物:SCIE、EI、Scopus

卷号:112

页面范围:1083-1094

ISSN号:1359-4311

关键字:Coupled heat and mass transfer; Ground source; Heat pump system; Unsaturated porous medium

摘要:This research presents an unsaturated three-dimensional model to study a ground source heat pump system based on moisture porous theory and soil moisture dynamics. The experiments are performed under the same condition as in the numerical methods. The soil temperature along 50 m deep of the U tube shows good agreement with the simulation results. The shallow soil temperature decreases by approximately 0.5-0.9 degrees C, during the heating period, when the infiltration and evaporation are considered by adding a source phase equation on the same operation time. The infiltration-influencing factors (e.g. soil moisture rate and soil saturated hydraulic conductivity) and the evaporation-influencing factors (e.g. soil saturated moisture content) are also calculated. The soil temperature decreases by approximately 5-8% as the influencing factors increase by 50-100%. Furthermore, the effect on the shallow soil is obvious, especially at a depth of 5 m and attenuates with the soil depth. (C) 2016 Elsevier Ltd. All rights reserved.