High-Sensitivity Fabry-Perot Interferometric Acoustic Sensor for Low-Frequency Acoustic Pressure Detections

点击次数:

论文类型:期刊论文

发表时间:2017-12-15

发表刊物:JOURNAL OF LIGHTWAVE TECHNOLOGY

收录刊物:SCIE、EI、Scopus

卷号:35

期号:24

页面范围:5276-5279

ISSN号:0733-8724

关键字:Acoustic pressure detection; Fabry-Perot; fiber optics sensors

摘要:We demonstrate a fiber-optic Fabry-Perot acoustic sensor based on a Parylene-C diaphragm of 500 nm in thickness. The excellent diaphragm forming ability and good adhesion of Parylene-C make the sensor fabricate up to 9 mm in diameter. Acoustic testing demonstrates a high dynamic pressure sensitivity of 2239 nm/Pa and a noise limited equivalent acoustic signal level of 22.1 mu Pa/Hz(1/2) at the frequency of 20 Hz. The frequency response exhibits an obvious peak at the frequency of 13 Hz. The sensor can be used for low-frequency acoustic pressure detections, which is necessary in surveillance and security systems.