Release Time:2019-03-12 Hits:
Indexed by: Journal Article
Date of Publication: 2006-01-01
Journal: 13th Conference on Abrasive Technology in China
Included Journals: CPCI-S、EI、SCIE
Volume: 304-305
Page Number: 127-130
ISSN: 1013-9826
Key Words: grinding; temperature; thermocouple; dynamic response error; compensation
Abstract: In order to improve grinding temperature measuring precision the compensation method of thermocouple dynamic response errors and the modification method of non-linearity of thermocouple characteristic curve were analyzed and then programmed with VC++ language. Further more a grinding temperature measuring system was developed by means of second development of 10612CF type of TOP DAC (data acquiring card) with Labwindows/CVI, which provides three kinds of estimating thermocouple time constant methods. Primary debugging results showed that the measuring system developed is simply easy to handle and can satisfy experimental study of grinding temperature.