location: Current position: Home >> Scientific Research >> Paper Publications

Error calibration of controlled rotary pairs in five-axis machining centers based on the mechanism model and kinematic invariants

Hits:

Indexed by:期刊论文

Date of Publication:2017-09-01

Journal:INTERNATIONAL JOURNAL OF MACHINE TOOLS & MANUFACTURE

Included Journals:SCIE、EI、Scopus

Volume:120

Page Number:1-11

ISSN No.:0890-6955

Key Words:Error calibration; Motion measurement; Rotary pair; Ball bar; Kinematic invariants; Five-axis machining center

Abstract:The mechanism model of ball bar testing for a two-axis rotary table of 5-axis machining center is discussed, and a new ball bar method to measure the three-dimensional motions of the rotary pairs in multi-axis machining center is developed based on the mechanism model. Then, the fixed axes and moving axes of the rotary pairs are identified by using spherical image circle fitting and striction circle fitting, according to the kinematic invariants of nominal rotation and the measured motions. The structure errors and kinematic pair errors of the rotary pairs are defined and identified by using the fixed and moving axes, and the kinematic model of the two-axis rotary table is deduced with those errors. The simultaneous two-axis motions of the rotary table are measured to verify the proposed calibration method. The experimental results show good agreements with the predicted results calculated by the calibrated kinematic model. Furthermore, the accuracy of the simultaneous multi-axis motions of the machining center is improved when the identified errors are corrected.

Pre One:移动副离散误差运动的不变量评价方法