高强混凝土短柱抗剪承载力试验研究
Hits:

Date of Publication:2001-01-01

Journal:大连理工大学学报

Issue:1

Page Number:104-107

ISSN No.:1000-8608

Abstract:With the wide application of high-strength concrete, thehigh-strength concrete short columns are frequently met in high-rise buildings. There are differences on mechanics performances such as shear strength between high-strength concrete and normal concrete. The shear strength test of high-strength concrete frame short columns under axial and horizontal load is carried out. Affecting factors on shear strength, such as concrete strength, axial pressure ratio and shears panratio, etc., are analyzed. A very important conclusion is reached: The shear strength increases with the axial pressure ratio; But when axial pressure ratio is greater than 0.4, the shear strength increases slowly. The shear strength fo rmula of high-strength concrete frame short columns is obtained through the test. The calculated results are corresponding with those of the tests very well.

Note:新增回溯数据

Personal information

Professor
Supervisor of Doctorate Candidates
Supervisor of Master's Candidates

Gender:Male

Alma Mater:大连理工大学

Degree:Doctoral Degree

School/Department:能源与动力学院

Discipline:Thermal Engineering. Chemical Engineering. Operation Research and Control Theory

Business Address:大连理工大学能源与动力学院712室

Contact Information:电话:13940865971 邮箱:hcyin@dlut.edu.cn

Click:

Open time:..

The Last Update Time:..


Address: No.2 Linggong Road, Ganjingzi District, Dalian City, Liaoning Province, P.R.C., 116024