Hits:
Indexed by:期刊论文
Date of Publication:2013-02-01
Journal:INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER
Included Journals:SCIE、EI
Volume:41
Page Number:63-67
ISSN No.:0735-1933
Key Words:Thermal contact conductance; Experimental investigation; Hastelloy C-276; SS302; Rotor can; Shrink fit
Abstract:In this study, measurements of the thermal contact conductance (TCC) at the interfaces of Hastelloy C-276/Hastelloy C-276 and Hastelloy C-276/SS302 test pairs were conducted by a self-developed experimental setup based on the steady-state heat flux method. The reliability of experimental setup and method was validated by the repeated measurement of the thermal contact conductance between Hastelloy C-276 and Hastelloy C-276. In addition, the effects of contact pressure and interfacial temperature on thermal contact conductance were also discussed. This study not only provides a necessary database for the accurate numerical simulation but also lays a foundation for the optimal design of the shrink fitting process of rotor can. (C) 2012 Elsevier Ltd. All rights reserved.