Hits:
Indexed by:期刊论文
Date of Publication:2022-06-29
Journal:光电子 激光
Volume:21
Issue:4
Page Number:485-488
ISSN No.:1005-0086
Abstract:A novel flat heat pipe radiator is put forward and the experimental
investigation on heat transfer performance of the flat heat pipe
radiator for cooling high power LED array is established. The startup
performance, temperature uniformity of the flat heat pipe radiator and
the effects of the heat load and tilt angle on the thermal
characteristics in natural convection are analyzed. An
electrical-thermal conversion method is used to measure the junction
temperature of the high power LED. It is found that the total thermal
resistance of the flat heat pipe radiator varies in the range of 0. 3053
℃/W-0. 3425 ℃/W and it has a reasonable and uniform temperature
distribution. The junction temperature of the LED array varies in the
range of 47.9 ℃-59. 0 ℃ and is far lower than 110 ℃.
Note:新增回溯数据