端木琳

个人信息Personal Information

教授

博士生导师

硕士生导师

性别:女

毕业院校:大连理工大学

学位:博士

所在单位:土木工程系

学科:供热、供燃气、通风及空调工程. 热能工程

办公地点:大连理工大学土木工程学院综合实验4号楼431室

电子邮箱:duanmu@dlut.edu.cn

扫描关注

论文成果

当前位置: 中文主页 >> 科学研究 >> 论文成果

Building air leakage analysis for individual apartments in North China

点击次数:

论文类型:期刊论文

发表时间:2017-09-01

发表刊物:BUILDING AND ENVIRONMENT

收录刊物:Scopus、SCIE、EI

卷号:122

页面范围:105-115

ISSN号:0360-1323

关键字:Apartment; Airtightness; Natural ventilation; Energy conservation; Indoor air quality

摘要:There is little known on the airtightness performance of apartment building in China. The present study intends to investigate the airtightness performance of twelve individual apartments from four buildings in China's cold area using the blower door method. The air leakage of two building components of each of the three individual apartments from the 4# building was further investigated by a series of blower door tests. The normality test was performed to the test results, and the correlation coefficients between the air leakage and possible influence factors were analyzed.
   Test results show that the air change rate of the tested individual apartments at 50Pa changes from 1.14 h(-1) to 2.44 h(-1) with an average of 1.77 h(-1). The check valves at the inlets of the discharge flue and exhaust airway were tested to be leakier than the outer windows and doors in the three measured apartments from the 4# building. Results of statistical analysis show that the data was significantly drawn from a normally distributed population at the 0.05 significance level, and the envelope area and the joint length of the opening part of the windows and doors were identified as the main factors that influence the air leakage of the tested apartments at the 0.05 significance level. (C) 2017 Elsevier Ltd. All rights reserved.