Hits:
Indexed by:会议论文
Date of Publication:2007-10-23
Included Journals:EI、CPCI-S
Page Number:510-512
Key Words:blower; numerical simulation; experimental investigation; electric locomotive
Abstract:A cooling fan on electric locomotive was designed based on one-dimensional calculation and three-dimensional numerical simulation. Three-dimensional model was presented based on the one-dimensional calculation. Numerical simulation and thorough analysis were carried out on the blower with software NUMECA, which was used for turbomachine. The performance experiment of the improved blower was studied. The experimental data shows that the performance of the optimized axial cooling fan is better than the original one. Especially the melioration of the efficiency and noises. The inlet and outlet flow field is much steady. The optimized blower was better than the same style of imported one in performance.