location: Current position: Home >> Scientific Research >> Paper Publications

Analysis of adjusting method for load performance of TVC-MED desalination plant

Hits:

Indexed by:期刊论文

Date of Publication:2013-01-01

Journal:International Conference of the European-Desalination-Society on Desalination for the Environment, Clean Water and Energy

Included Journals:SCIE、CPCI-S

Volume:51

Issue:4-6

Page Number:857-862

ISSN No.:1944-3994

Key Words:Multi-effect distillation; Thermal vapor compressor; Adjusting method; Load performance

Abstract:Multi-effect distillation (MED) desalination with thermal vapor compressor (TVC) is widely used in a dual-purpose power plant configuration. Due to the variety of extraction pressure and water demand, it works under a wide range varying from over-rated load to less than half-rated load. The adjusting method of load performance is presented to obtain the optimal performance of MED-TVC desalination plant based on the operating characteristics of TVC and MED. With adjustable TVC, the thermodynamic performance of MED-TVC is analyzed when water load and extraction pressure varies. The effect of the variation in feed seawater flow rate, together with the heating steam temperature of the first evaporator, is also investigated. The results of the analysis are fairly close to the data of a practical MED-TVC plant, which justifies the expectation that the analytical method is accurate and reliable.

Pre One:CFD Anaysis of Nozzle Gometry on Injector Performance

Next One:Numerical analysis of thermodynamic behaviour of falling film outside a horizontal tube