Hits:
Indexed by:会议论文
Date of Publication:2009-03-09
Included Journals:EI、Scopus
Volume:7292
Issue:PART 1
Abstract:Accurate measurement of strain variation and effective prediction of failure within models has been a major objective for strain sensors in dam model tests. In this paper, a FBG strain sensor with enhanced strain sensitivity and packaged by two gripper tubes is presented and applied in the seismic tests of a small scale dam model. This paper discusses the principle of enhanced sensitivity of the FBG strain sensor. Calibration experiments were conducted to evaluate the sensor's strain transferring characteristics on plates of different material. This paper also investigates the applicability of the FBG strain sensors in seismic tests of a dam model by conducting a comparison between the test measurements of FBG sensors and analytical predictions, monitoring the failure progress and predicting the cracking inside the dam model. Results of the dam model tests prove that this FBG strain sensor has the advantages of small size, high precision and embedability, demonstrate promising potential in cracking and failure monitoring and in identification of the dam model. ? 2009 SPIE.