location: Current position: Home >> Scientific Research >> Paper Publications

Structural Health Monitoring System Developed for Dalian Stadium

Hits:

Indexed by:期刊论文

Date of Publication:2016-05-01

Journal:INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS

Included Journals:SCIE

Volume:16

Issue:4,SI

ISSN No.:0219-4554

Key Words:Stadium; structure health monitoring system; fiber Bragg grating (FBG)

Abstract:The peripheral structure of Dalian stadium is a long-span spatial truss structure. To ensure the safety of the peripheral structure during construction and operation period, the permanent structure health monitoring system is implemented. This paper first introduces the structural features of the Dalian stadium, and then illustrates the permanent monitoring program from the aspects of the hardware, the monitoring scheme and the function. This developed monitoring system is utilized to monitor the stress of the truss, and the dynamic response of the structure. Large amounts of data are obtained through the health monitoring system, and thus the safe condition of the structure can be evaluated based on data analysis.

Pre One:Study on an innovative self-inductance tension eddy current sensor based on the inverse magnetostrictive effect

Next One:基于光纤光栅应变箍传感器的管道局部腐蚀监测