location: Current position: Home >> Scientific Research >> Paper Publications

Experimental study on the corrosion of buried directly heating supply pipeline based on the BOTDA (R) technique

Hits:

Indexed by:期刊论文

Date of Publication:2013-06-01

Journal:Sensors and Transducers

Included Journals:EI、Scopus

Volume:22

Issue:SPEC.ISSUE

Page Number:74-80

ISSN No.:17265479

Abstract:A novel Brillouin Optical Time Domain Analysis sensors, BOTDA(R), has been developed, which can monitor steel corrosion in concrete structures and various insulation structures. The application of distributed BOTDA(R) technology in heating supply pipe corrosion detection is discussed in this paper. According to the characteristics of derictly buried heating supply pipe, we have designed the optical fiber corrosion sensors for the prefabricated pipe, and the sensors were arranged in the junction of pipe section. Accelerated corrosion tests were used to demo the acid soil environment. Quantitative evaluation was derived formula for steel pipe corrosion. ? 2013 by IFSA.

Pre One:管网质调节运行时散热器的动态热过程分析

Next One:An investigation on the cooling characteristics of impingement-reversed convection film cooling in a curved section