location: Current position: Home >> Scientific Research >> Paper Publications

Fault Tolerant Control of a Truss Structure Using MR Dampers

Hits:

Indexed by:会议论文

Date of Publication:2010-01-01

Included Journals:CPCI-S

Page Number:302-305

Key Words:Fault tolerant control; Semi-active control; Roubust Control; MR dampers; Fault detection and isolation

Abstract:This paper presents the design and application of an Hco fault detection and isolation (FDI) filter and fault tolerant controller (FTC) for truss vibration control systems using MR dampers. A linear matrix inequality (LMI) formulation is used to design a full order robust Hoo filter to estimate faulty input signals. A fault tolerant Hoo controller is designed for the combined system of plant and filter, minimizing the control objective selected in the presence of disturbances and faults. A truss structure with an MR damper is used to validate the FDI and FTC controller design through numerical simulations. The residuals obtained from the filter through simulation clearly identify the fault signals. The simulation results of the proposed FTC controller confirm its effectiveness for vibration suppression of the faulty truss system.