吴硕

个人信息Personal Information

教授

博士生导师

硕士生导师

主要任职:化学学院副院长

其他任职:辽宁省教学名师,宝钢优秀教师特等奖提名奖,中国分析测试学会青年学术委员会委员

性别:女

毕业院校:南京大学

学位:博士

所在单位:化学学院

学科:分析化学. 生物化学与分子生物学

办公地点:化工综合楼C305

电子邮箱:wushuo@dlut.edu.cn

扫描关注

论文成果

当前位置: 中文主页 >> 科学研究 >> 论文成果

Phosphonate-Substituted Ruthenium(II) Bipyridyl Derivative as a Photoelectrochemical Probe for Sensitive and Selective Detection of Mercury(II) in Biofluids

点击次数:

论文类型:期刊论文

发表时间:2018-12-18

发表刊物:ANALYTICAL CHEMISTRY

收录刊物:SCIE、PubMed、Scopus

卷号:90

期号:24

页面范围:14423-14432

ISSN号:0003-2700

关键字:Body fluids; Chromophores; Electrochemistry; Energy gap; Mercury compounds; Nanoparticles; Organic polymers; Photocurrents; Photoelectrochemical cells; Photoelectrons; Photons; Probes; Synthesis (chemical); Tin oxides; Titanium dioxide, Analytical performance; Conduction band energy; Photocurrent response; Photoelectrochemicals; Photophysical properties; Selective detection; Separation efficiency; Specific recognition, Ruthenium compounds

摘要:A ruthenium(II) bipyridyl derivative photoelectrochemical probe, Ru-1, is synthesized and coupled with TiO2 nanoparticles (Ru-1/TiO2) for the specific recognition and highly sensitive photoelectrochemical (PEC) detection of Hg2+ in a series of biofluids. The probe is designed with a chromophore, a thiocyanate recognition unit, a pi-conjugated photoelectron-transfer pathway, and a phosphonate anchor. TiO2 nanoparticles with strong affinity to phosphonate and suitable conduction band energy are used as intermediate layers to increase the Ru-1 adsorption amount and amplify the photocurrent response. Under irradiation, the Ru-1/TiO2/fluorine-doped tin oxide (FTO), with strong visible light harvesting capacity, aqueous stability, and efficient photoelectron transfer, shows a high and stable photocurrent response. In the presence of Hg2+, however, the specific Hg2+ and NCS coordination changes the photophysical properties of Ru-1, imposing the probe with a wider band gap, a weaker absorbance, and a poorer photoelectron and hole separation efficiency, thus resulting in a significant photocurrent decrease. On the basis of the Hg2+-induced photocurrent change, the Ru-1/TiO2/FTO shows good selectivity and high sensitivity toward the PEC detection of Hg2+, with wide linear ranges from 10(-12) to 10(-7) and 10(-7) to 10(-3) g/mL, and a low limit of detection of 0.63 pg/mL. The PEC probe is recyclable and accurate for selective detection of Hg2+ in urine, serum, and cell extracts. The whole analysis can be completed within 15 min. These good analytical performances indicate that the PEC method might have great potential for the onsite detection of small molecules in biosystems.