location: Current position: Home >> Scientific Research >> Paper Publications

Experimental investigation of transient contact heat transfer between 300M and 5CrNiMo

Hits:

Indexed by:期刊论文

Date of Publication:2016-05-01

Journal:INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER

Included Journals:SCIE、EI

Volume:96

Page Number:451-457

ISSN No.:0017-9310

Key Words:Thermal contact conductance; Transient contact heat transfer; 300M; 5CrNiMo; Experimental investigation

Abstract:The contact heat transfer between 300M steel and 5CrNiMo die steel has an important influence on the hot forging process of 300M steel. The accurate thermal contact conductance data are needed for the optimal design and numerical simulation of the hot forging process of 300M steel. Consequently, in this study, a set of new experimental apparatus and relevant procedure were developed to measure the thermal contact conductance at the interface between 300M and 5CrNiMo based on the transient method. The effects of the initial temperature of the 300M specimen, the interfacial pressure, the oxide layer and the graphite lubricant on the thermal contact conductance were evaluated. (C) 2016 Elsevier Ltd. All rights reserved.

Pre One:Improvement of Surface Ridging Resistance of an Ultra-purified Ferritic Stainless Steel by Optimizing Hot Rolling Condition

Next One:Constitutive Analysis of Dynamic Recrystallization and Flow Behavior of a Medium Carbon Nb-V Microalloyed Steel