闫兴清
Personal Homepage
Paper Publications
Duct-venting of dust explosions in a 20 L sphere at elevated static activation overpressures
Hits:

Indexed by:期刊论文

Date of Publication:2014-11-01

Journal:JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES

Included Journals:SCIE、EI

Volume:32

Issue:1

Page Number:63-69

ISSN No.:0950-4230

Key Words:Dust explosion; Duct venting; Vent duct; Secondary explosion

Abstract:Ducts are often recommended in the design of dust explosion venting in order to discharge materials to safe locations. However, the maximum reduced overpressure increases in a duct-vented vessel rather than in a simply vented vessel. This needs to be studied further for understanding the duct-venting mechanism. Numerous duct-vented dust explosion experiments were conducted, using a 20 L spherical chamber at elevated static activation overpressures, ranging from 1.8 bar to 6 bar. Duct diameters of 15 mm and 28 mm, and duct lengths of 0 m (simply venting), I m and 2 m, were selected. Explosion pressures both in the vessel and in the duct were recorded by pressure sensors, with a frequency of 5 kHz. Flame signals in the duct were also obtained by phototransistors. Results indicate that the secondary explosion occurring in the duct increases the maximum reduced overpressure in the vessel. The secondary explosion is greatly affected by the duct diameter and static activation overpressure, and hence influences the amplification of the maximum reduced overpressure. Larger static activation overpressure decreases the severity of the secondary explosion, and hence decreases the increment in the maximum reduced overpressure. The secondary pressure peak is more obvious as the pressure accumulation is easier in a duct with a smaller diameter. However, the increment of the maximum reduced overpressure is smaller because blockage effect, flame front distortion, and turbulent mixing due to secondary explosion are weaker in a narrow duct. The influence of duct length on the maximum reduced overpressure is small at elevated static activation overpressures, ranging from 1.8 bar to 6 bar at 15 mm and 28 mm duct diameters. (C) 2014 Elsevier Ltd. All rights reserved.

Personal information

Engineer

Gender:Male

Alma Mater:大连理工大学

Degree:Doctoral Degree

School/Department:化工学院

Discipline:Chemical Process Equipment. Safety Science and Engineering

Business Address:大连理工大学西校区H509

Contact Information:13478665105

Click:

Open time:..

The Last Update Time:..


Address: No.2 Linggong Road, Ganjingzi District, Dalian City, Liaoning Province, P.R.C., 116024

MOBILE Version