论文成果
联系我们
连志强老师:电话:18641181139

电邮:lianzq75@dlut.edu.cn
当前位置: 中文主页 >> 研究成果 >> 论文成果
Lock-in infrared thermography for non-destructive testing of grid stiffened composite structure
发表时间:2019-03-11 点击次数:
论文类型:期刊论文
第一作者:Zhao Y.
通讯作者:Guo, X.; State Key Laboratory of Structural Analysis for Industrial Equipment, Dalian University of Technology, Dalian 116024, China
合写作者:Guo X.,Ren M.
发表时间:2012-01-01
发表刊物:Advanced Science Letters
收录刊物:Scopus
文献类型:J
卷号:5
期号:2
页面范围:593-596
ISSN号:19366612
摘要:In this paper, a non-destructive testing of grid stiffened composite structure with typical defects is presented based on the lock-in infrared thermography technology. The results are analyzed using lock-in infrared thermography system developed by Cedip in France. The effects of loading frequency and output voltage offset on test results are discussed. However, it is shown that the position and shape of the defects could be inspected, but not clear at the boundary. The proper loading frequency should be chosen for different attributes of materials and types of defects. And to increasing the output voltage offset is also good for the test. This method is feasible to inspect the unknown defect of composite materials. ? 2012 American Scientific Publishers All rights reserved.
是否译文: