Release Time:2019-03-11 Hits:
Indexed by: Conference Paper
Date of Publication: 2015-05-23
Included Journals: Scopus、CPCI-S、EI
Page Number: 754-759
Key Words: Glutamic Solution Concentration; Crystallization Process; Partial Least Squares
Abstract: Online monitoring of glutamic solution concentration is very important to control the crystallization process. Using infrared spectrometer ReactIR 15, we can obtain the real-time spectral data. Based on the partial least squares regression method, We can establish the regression model between glutamic solution concentration and the real-time spectral data. Repeated calibration experiments based on this model show that the average error is 0.53, and the average relative error is 1.88%. The model has good prediction ability, and it realized online monitoring of glutamic solution concentration in crystallization process. This paper proposed a good reference frame for the online analysis of solution concentration in crystallization process.