location: Current position: Home >> Scientific Research >> Paper Publications

Recycled aggregate concrete filled steel SHS beam-columns subjected to cyclic loading

Hits:

Indexed by:期刊论文

Date of Publication:2009-02-01

Journal:STEEL AND COMPOSITE STRUCTURES

Included Journals:SCIE

Volume:9

Issue:1

Page Number:19-38

ISSN No.:1229-9367

Key Words:recycled aggregate concrete filled steel tube (RACFST); recycled aggregate concrete (RAC); composite columns; cyclic loads; capacity; flexural stiffness; ductility

Abstract:The present paper provides test data to evaluate the seismic performance of recycled aggregate concrete (RAC) filled steel square hollow section (SHS) beam-columns. Fifteen specimens, including 12 RAC filled steel tubular (RACFST) columns and 3 reference conventional concrete filled steel tubular (CFST) columns, were tested under reversed cyclic flexural loading while subjected to constant axially compressive load. The test parameters include: (1) axial load level (n), from 0.05 to 0.47; and (2) recycled coarse aggregate replacement ratio (r), from 0 to 50%. It was found that, generally, the seismic performance of RACFST columns was similar to that of the reference conventional CFST columns, and RACFST columns exhibited high levels of bearing capacity and ductility. Comparisons are made with predicted RACFST beam-column bearing capacities and flexural stiffness using current design codes. A theoretical model for conventional CFST beam-columns is employed in this paper for square RACFST beam-columns. The predicted load versus deformation hysteretic curves are found to exhibit satisfactory agreement with test results.

Pre One:Experimental Performance of Recycled Aggregate Concrete-Filled Circular Steel Tubular Columns Subjected to Cyclic Flexural Loadings

Next One:火灾下方形耐火钢管混凝土柱的性能