Chen Jianyun

Professor   Supervisor of Doctorate Candidates   Supervisor of Master's Candidates

Gender:Male

Alma Mater:大连理工大学

Degree:Doctoral Degree

School/Department:水利工程系

Discipline:Hydraulic Structure Engineering. Disaster Prevention & Mitigation Engineering. Structural Engineering. Project Management

Contact Information:QQ:593001776

E-Mail:eerd001@dlut.edu.cn


Paper Publications

Numerical simulation and investigation of the base isolated NPPC building under three-directional seismic loading

Hits:

Indexed by:期刊论文

Date of Publication:2013-12-01

Journal:NUCLEAR ENGINEERING AND DESIGN

Included Journals:SCIE、EI、Scopus

Volume:265

Page Number:484-496

ISSN No.:0029-5493

Abstract:Reinforced concrete containment (RCC) is the most significant component of the nuclear power plant (NPP). Therefore, the safety and integrity must be ensured during the plant life in any conditions, in particular, in the event of a severe earthquake. Seismic or base isolation is a proven technology for reducing the effects of earthquake shaking on the building and avoiding failure of structure under earthquake. The aim of this paper is to numerically analyze the dynamic response of the RCC with or without high damping rubber bearing (HDRB) isolators, in the event of three Safe Shutdown Earthquakes (SSEs), accomplished by means of the finite element approach and setting up, as accurately as possible, a representative three-dimensional model of mentioned nuclear power plant containment (NPPC) structure. The obtained seismic analyses results in terms of accelerations, propagated from the ground to the building, base shear and displacements are compared for isolated and non-isolated NPPC to validate the reliability of the isolation technology in mitigating structural response. Furthermore, a new decreasing amplitude ratio (DAR) of structure response for the NPP structure is also proposed to estimate the effectiveness of the isolation system. In addition, the study shows that the patterns for non-isolated structure are mainly oscillating motion, whereas in case of seismic isolation they are associated to pure lateral translation. Therefore, it needs to consider the optimum of compatibility for connecting pipelines between the isolated and non-isolated buildings in the design. (C) 2013 Elsevier B.V. All rights reserved.

Pre One:Dynamic characteristics of AP1000 shield building for various water levels and air intakes considering fluid-structure interaction

Next One:内爆荷载作用下钢筋混凝土安全壳的非线性响应分析

Profile


2004 -博士生导师,大连理工大学土木水利学院
2006- 教授,大连理工大学土木水利学院
2007- 2008 研究生院副院长
2009 - 2014 建设工程学部水利学院 副院长
1999 -2004 副教授,大连理工大学土木水利学院 ,工程抗震研究所副所长