摘要:For huge complex structures, it is difficult to obtain enough
information which is required necessarily in their global monitoring.
Aiming at this problem, a Substructure Isolation Method (SIM) is
proposed for local damage identification. An isolated substructure is a
virtual and independent structure, which is separated from a global
structure by adding virtual supports on the substructure boundary to
zero the substructure boundary responses. Correspondingly the interior
responses of the isolated substructure are constructed and used to
identify the local substructure damage equivalently. In order to reveal
the essence of the Substructure Isolation Method and unify its basic
concept, the way of arranging sub-time series is improved according to
the SIM method based on impulse response, that is, sub-time series are
extracted section by section, and then are arrayed into a Toeplitz
matrix. In this way, it not only unifies the expression of SIM based on
local time series and that based on impulse response, but also
integrates the basic concept of SIM. An experiment of a cantilever beam
is used to validate the efficiency and the practical application of this
method. Both the substructure isolation and damage identification are
performed successfully using local measured responses.