location: Current position: Home >> Scientific Research >> Paper Publications

Fiber-optic anemometer based on single-walled carbon nanotube coated tilted fiber Bragg grating

Hits:

Indexed by:期刊论文

Date of Publication:2017-10-02

Journal:OPTICS EXPRESS

Included Journals:Scopus、SCIE、EI

Volume:25

Issue:20

Page Number:24521-24530

ISSN No.:1094-4087

Abstract:In this work, a novel and simple optical fiber hot-wire anemometer based on single-walled carbon nanotubes (SWCNTs) coated tilted fiber Bragg grating (TFBG) is proposed and demonstrated. For the hot-wire wind speed sensor design, TFBG is an ideal in-fiber sensing structure due to its unique features. It is utilized as both light coupling and temperature sensing element without using any geometry-modified or uncommon fiber, which simplifies the sensor structure. To further enhance the thermal conversion capability, SWCNTs are coated on the surface of the TFBG instead of traditional metallic materials, which have excellent thermal characteristics. When a laser light is pumped into the sensor, the pump light propagating in the core will be easily coupled into cladding of the fiber via the TFBG and strongly absorbed by the SWCNTs thin film. This absorption acts like a hot-wire raising the local temperature of the fiber, which is accurately detected by the TFBG resonance shift. In the experiments, the sensor's performances were investigated and controlled by adjusting the inherent angle of the TFBG, the thickness of SWCNTs film, and the input power of the pump laser. It was demonstrated that the developed anemometer exhibited significant light absorption efficiency up to 93%, and the maximum temperature of the local area on the fiber was heated up to 146.1 degrees C under the relatively low pump power of 97.76 mW. The sensitivity of -0.3667 nm/(m/s) at wind speed of 1.0 m/s was measured with the selected 12 degrees TFBG and 1.6 mu m film. (C) 2017 Optical Society of America

Pre One:Refractive Index Measurement of Liquid Based on Open Fiber Fabry-Perot Interferometer

Next One:A Novel Fiber Optic Surface Plasmon Resonance Biosensors with Special Boronic Acid Derivative to Detect Glycoprotein