Current position: Home >> Scientific Research >> Paper Publications

Magnesium alloy weld using manganese chloride coated wire

Release Time:2019-03-10  Hits:

Indexed by: Journal Article

Date of Publication: 2008-01-01

Journal: SCIENCE AND TECHNOLOGY OF WELDING AND JOINING

Included Journals: EI、SCIE

Volume: 13

Issue: 1

Page Number: 44-48

ISSN: 1362-1718

Key Words: magnesium alloy; flux coated wire; weld bead penetration; arc constriction

Abstract: Magnesium alloy was welded with normal wire and activated flux coated wire. Weld bead penetration, arc voltage, arc profiles and welding arc electronic temperature were researched. Weld bead penetration, arc voltage and welding arc electronic temperature increased when activated flux coated wire was used. It is also found that the welding arc constricted in flux coated wire weld. It is believed that deep weld penetration associated with flux coated wire in this experiment is caused by arc constriction.

Prev One:Mechanical properties and microstructures of a magnesium alloy gas tungsten arc welded with a cadmium chloride flux

Next One:单一及复合氧化物活性剂对镁合金A-TIG焊的影响