location: Current position: Home >> Scientific Research >> Paper Publications

Delay Calculation of Field-Breakdown Triggered Vacuum Switch

Hits:

Indexed by:会议论文

Date of Publication:2010-01-01

Included Journals:CPCI-S、SCIE、Scopus

Page Number:55-58

Key Words:Triggered vacuum switch (TVS); initial plasmas; delay

Abstract:Triggered vacuum switch (TVS) is one of the important switch apparatuses in the fields of pulsed power system, due to its quick switch, rapid dielectric recovery, small volume, convenient trigger system, and simple structure, etc. A sample of field-breakdown TVS was fabricated and its turning-on experiments were done. Initial plasmas played an important role in the turning-on process of TVS, so the delay of TVS was tested, including wait time t(1) and collapse time t(2), and it could implicate the needed time of development of initial plasmas. From thermodynamics equations, a model of cathode spots heat conduction was set up. A formula deduced from the heat conduction model could calculate the delay of TVS. Calculated results of t(1) and t(2) were accordant with the tested results.

Pre One:Fiber-Controlled Vacuum Interrupter Module Used for Fault Current Interruption

Next One:Study on Breaking Characteristics of High Voltage Hybrid Circuit Breaker