廖敏夫

个人信息Personal Information

教授

博士生导师

硕士生导师

性别:男

毕业院校:大连理工大学

学位:博士

所在单位:电气工程学院

学科:电机与电器. 高电压与绝缘技术. 电力电子与电力传动

办公地点:大连理工大学电气工程学院电力电子研究所407

联系方式:mfliao@dlut.edu.cn

电子邮箱:mfliao@dlut.edu.cn

扫描关注

论文成果

当前位置: 中文主页 >> 科学研究 >> 论文成果

Operational characteristics of a field-breakdown triggered vacuum switch

点击次数:

论文类型:会议论文

发表时间:2008-06-10

收录刊物:EI、Scopus

页面范围:518-521

摘要:Triggered vacuum switch (TVS) is one of the important switch apparatuses in the fields of high-pulsed power system. Its working lifetime is due to trigger failure of the trigger pin, so the parameters of trigger source become the key of lifetime dilatation. A sample of field-breakdown TVS coated with nothing is fabricated, which has much longer lifetime than the TVS coated with trigger materials, but more trouble in the trigger process. A trigger system and a LC test circuit are designed to find the operational characteristics of the TVS sample. The trigger system generates a negative pulse with peak value of 30kV/500A, the system delay and its scatter is controlled in 70-100μs, and the triggered rate of success reaches 96%. Test results show that the sample has a wide working voltage range of 0.3-40kV. The delay of its switching-on is stable in hundreds of nanoseconds, which will be reduced with the increase of main gap voltage. The arcing is steady in the conducting process, keeping arc voltage at 20V approximately. The arc current drops to zero as current zero is approached, leading to a voltage remained in the capacitance. ©2008 IEEE.