卷号:7647
关键字:Reinforcing Steel; Corrosion Monitoring; Corrosion Sensor; Electrochemical Method
摘要:Health degradation by corrosion of steel in civil engineering, especially in rough environment, is a persistent problem. Structural health monitoring (SHM) techniques can lead to improved estimates of structural safety and serviceability. A novel all solid state-current confined corrosion sensor has been developed to provide the platform for corrosion monitoring of the steel bar in concrete beam by electrochemical method. Finite element method has been used to certify the current confined effect of the sensor. The sensors have been used in concrete beams to monitor the corrosion of the steel bar. Also, half-cell potential of the beam has obtained. The results shows that the corrosion sensor can effectively confine the current in the fixed area which is 45mmx pi xD(steel) (bar) and the monitoring results of the corrosion sensor are accurate.