• 其他栏目
    • 语种

    欧进萍

    • 教授     博士生导师
    • 性别:男
    • 毕业院校:哈尔滨建筑大学
    • 学位:博士
    • 所在单位:建设工程学院
    • 电子邮箱:

    访问量:

    开通时间:..

    最后更新时间:..

    移动版主页

    论文成果

    当前位置: 中文主页 >> 科学研究 >> 论文成果
    Brillouin Corrosion Expansion Sensors for Steel Reinforced Concrete Structures Using a Fiber Optic Coil Winding Method

    点击次数:

      发布时间:2019-03-09

      论文类型:期刊论文

      发表时间:2011-11-01

      发表刊物:SENSORS

      收录刊物:PubMed、SCIE、Scopus

      卷号:11

      期号:11

      页面范围:10798-10819

      ISSN号:1424-8220

      关键字:fiber optic; Brillouin sensor; corrosion sensor; fiber optic coil; steel reinforced concrete structure; structural health monitoring

      摘要:In this paper, a novel kind of method to monitor corrosion expansion of steel rebars in steel reinforced concrete structures named fiber optic coil winding method is proposed, discussed and tested. It is based on the fiber optical Brillouin sensing technique. Firstly, a strain calibration experiment is designed and conducted to obtain the strain coefficient of single mode fiber optics. Results have shown that there is a good linear relationship between Brillouin frequency and applied strain. Then, three kinds of novel fiber optical Brillouin corrosion expansion sensors with different fiber optic coil winding packaging schemes are designed. Sensors were embedded into concrete specimens to monitor expansion strain caused by steel rebar corrosion, and their performance was studied in a designed electrochemical corrosion acceleration experiment. Experimental results have shown that expansion strain along the fiber optic coil winding area can be detected and measured by the three kinds of sensors with different measurement range during development the corrosion. With the assumption of uniform corrosion, diameters of corrosion steel rebars were obtained using calculated average strains. A maximum expansion strain of 6,738 mu epsilon was monitored. Furthermore, the uniform corrosion analysis model was established and the evaluation formula to evaluate mass loss rate of steel rebar under a given corrosion rust expansion rate was derived. The research has shown that three kinds of Brillouin sensors can be used to monitor the steel rebar corrosion expansion of reinforced concrete structures with good sensitivity, accuracy and monitoring range, and can be applied to monitor different levels of corrosion. By means of this kind of monitoring technique, quantitative corrosion expansion monitoring can be carried out, with the virtues of long durability, real-time monitoring and quasi-distribution monitoring.