• 更多栏目

    齐民

    • 教授     博士生导师   硕士生导师
    • 主要任职:Professor
    • 性别:男
    • 毕业院校:大连理工大学
    • 学位:博士
    • 所在单位:材料科学与工程学院
    • 学科:材料学. 生物医学工程
    • 办公地点:材料学院222房间
    • 联系方式:84708441
    • 电子邮箱:minqi@dlut.edu.cn

    访问量:

    开通时间:..

    最后更新时间:..

    聚乳酸-乙醇酸膜在模拟体液中降解的Monte Carlo 模拟

    点击次数:

    发表时间:2008-01-01

    发表刊物:中国组织工程研究与临床康复

    所属单位:材料科学与工程学院

    期号:6

    页面范围:1153-1156

    ISSN号:1673-8225

    摘要:BACKGROUND: Poly(lactic-co-glycolic acid) (PLGA) has been widely used as medical implants and drug vehicle. Due to various factors involved in the degradation process, it is rather difficult to simulate the mass loss properties of PLGA.OBJECTIVE: To investigate the mass loss properties of PLGA films, and observe the correlation between the stimulation and the factual measurement.DESIGN: Repeated measuring experiment. SETTING: School of Materials Science and Engineering, Dalian University of Technology.MATERIALS: PLGA 50:50, 70:30 and 75:25 with weight average molecular weight (Mw) of 63 000, 115 000 and 400 000 were purchased from Shandong Key Laboratory of Medical Polymer Materials, and 1,4-dioxane (analytically pure) was purchased from Tianjin No.1 Chemical Reagent Factory and used as solvent.METHODS: The experiments were carried out in the School of Materials Science and Engineering of Dalian University of Technology from April to July in 2006.①PLGA were dissolved in 1, 4-dioxane according to the mass ratio of 50:50, 70:30 and 75:25, and the solution were cast into 10 mm×10 mm×1 mm polymer films.②PLGA films were immersed in Hank's simulated body fluid (Ph 7.4) at 37 ℃, and then taken out every week (every 5 days for PLGA 50:50). The samples were washed and dried to measure the changes of number and Mw using gel permeation chromatography. Degradation velocity was also worked out. Meanwhile the mass loss properties of PLGA films were measured using electronic balance. Furthermore, an improved Monte Carlo method was applied to carry out the correlation analysis with experiment data. MAIN OUTCOME MEASURES: ①degradation rates of PLGA with different ratios of lactic acid and glycolic acid.②the correlation coefficient between simulation results and experiment data.RESULTS: ①The degradation rates for PLGA at 50:50, 70:30 and 75:25 were 0.058 5, 0.016 6 and 0.010 1 /d (based on Mn), or 0.061 0, 0.017 5 and 0.008 5 /d (based on Mw), respectively.②Correlation coefficients between simulation results and experiment data for PLGA 50:50, 70:30 and 75:25 were 0.973 6, 0.987 4 and 0.990 3 correspondingly. CONCLUSION:The numerical simulation results for the mass loss properties of PLGA fit the experiment data well.

    备注:新增回溯数据