Title of Paper:A TVAR parametric model applying for detecting anti-electric-corona discharge

Hits:

Date of Publication:2004-08-19

Included Journals:EI

Volume:3174

Page Number:607-612

Abstract:It is well known that the time-varying parametric model based on wavelet neural network has excellent performance on modeling a signal. The spark discharge signal is a typical nonstationary one. The spark discharge has two types in a static dust catcher. one is normal discharge, another is antielectric-corona discharge. A few simulations indicate that the performance of the TVAR model on modeling a discharge signal is fineness, especially, on distinguishing between normal discharge and anti-electric-corona discharge. © Springer-Verlag Berlin Heidelberg 2004. All rights reserved.