Hits:
Indexed by:Journal Papers
Date of Publication:2020-02-01
Journal:ENERGIES
Included Journals:EI、SCIE
Volume:13
Issue:4
Key Words:combined heat and power plant; real-time deep down-regulation market; cost of down-regulation; flexibility
Abstract:The issue of real-time deep down-regulation ancillary service has received increasing attention in the Northeast of China. Participation of combined heat and power plants with multitype units and flexible heating devices in the market is investigated. This paper establishes a model of feasible operating region and the coal consumption function for the combined heat and power plant. An internal optimal dispatch model and the minimum overall electric power output model for the plant satisfying a given heat load are presented. Furthermore, the models of total cost for down-regulation and average cost for deep down-regulation in two levels are established. These models are validated based on the realistic data of the plant in the Northeast of China. In case studies, the influence factors and change rules of the minimum electric power output, the total cost, and the average cost of plants are analyzed.