location: Current position: Home >> Scientific Research >> Paper Publications

Experimental investigation and numerical simulation for weakening the thermal fluctuations in a T-junction

Hits:

Indexed by:期刊论文

Date of Publication:2015-04-01

Journal:ANNALS OF NUCLEAR ENERGY

Included Journals:SCIE、EI

Volume:78

Page Number:180-187

ISSN No.:0306-4549

Key Words:Experimental investigation; Numerical simulation; Tee junction; Thermal fluctuation

Abstract:In this work, the mixing processes of hot and cold fluids with and without a distributor are predicted by experiments and numerical simulations using large-eddy simulation (LES) on FLUENT platform. Temperatures at different positions of the internal wall and mixing conditions caused by T-junctions at different times are obtained, then the simulated normalized mean and root-mean square (RMS) temperature, velocity vector and temperature contour for the two structures, namely with and without a distributor, are compared. The results show that, compared with the a T-junction without a distributor, the mixing region of hot and cold water in the T-junction with distributor moves to the middle of the pipe, and the inclusion of the distributor reduces the temperature fluctuations of internal wall noticeably and makes the mixing of hot and cold water more efficient. (C) 2015 Elsevier Ltd. All rights reserved.

Pre One:阳离子型聚丙烯酰胺水溶液的流变特性实验