个人信息Personal Information
教授
博士生导师
硕士生导师
主要任职:研究生院常务副院长
其他任职:辽宁省凝固控制与数字化制备技术重点实验室主任
性别:男
毕业院校:大连理工大学
学位:博士
所在单位:材料科学与工程学院
学科:材料加工工程
办公地点:研究生院;材料科学与工程学院
联系方式:tmwang@dlut.edu.cn
电子邮箱:tmwang@dlut.edu.cn
Effects of Co and Si additions and cryogenic rolling on structure and properties of Cu-Cr alloys
点击次数:
论文类型:期刊论文
发表时间:2019-01-07
发表刊物:MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING
收录刊物:SCIE、Scopus
卷号:740
页面范围:165-173
ISSN号:0921-5093
关键字:Cu-Cr-Co-Si alloys; Cryogenic rolling; Structure; Hardness; Strength; Electrical conductivity
摘要:Cu-Cr alloys have been widely used in industrial applications owing to their good combination of mechanical properties and electrical conductivity. However, the comprehensive performance of the alloy needs to be further improved to meet the harsh working environment. Hence, in this study, a new type of Cu-Cr alloy with Co and Si additions together with cryogenic rolling (CR) was designed and investigated. Microstructure analysis confirms that the Cr15Co9Si6 and Co2Si phases are formed with Co and Si additions into the Cu-Cr alloy. For the more, partial Cr15Co9Si6 phase decomposes during heat treatment process, and the Co2Si and Cr precipitates are precipitated from matrix during aging process. The improvement of tensile properties of the Cu-1Cr-1Co-0.6Si alloy is mainly attributed to the precipitation strengthening and grain boundary strengthening, and is also benefited from dislocation density strengthening, twin boundary strengthening, and solid solution strengthening. The electrical conductivity of the Cu-1Cr-1Co-0.6Si alloy decreases dramatically mainly due to the increase of impurity scattering caused by surplus Si atoms. CR deformation is helpful for more solute atoms precipitated from the supersaturated solid solution during aging process, and thus the electrical conductivity of the Cu-1Cr-1Co-0.6Si alloy increases with increasing deformation amount. After homogenizing treatment at 900 degrees C for 2 h, hot rolling by 60% at 900 degrees C, solution treating at 990 degrees C for 4 h, cold rolling by 90%, and aging at 440 degrees C for 1 h, the hardness, yield strength (YS), ultimate tensile strength (UTS), and electrical conductivity of the Cu-1Cr-1Co-0.6Si alloy are 214.6 HV, 663.7 MPa, 745.9 MPa and 41.6%IACS, respectively, which exhibit good mechanical properties with a proper electrical conductivity. These results provide a feasible route for developing high performance Cu-Cr alloys.