location: Current position: Home >> Scientific Research >> Paper Publications

Damage analysis of CFRP-confined circular concrete-filled steel tubular columns by acoustic emission techniques

Hits:

Indexed by:Journal Papers

Date of Publication:2015-08-01

Journal:SMART MATERIALS AND STRUCTURES

Included Journals:SCIE、EI、Scopus

Volume:24

Issue:8

ISSN No.:0964-1726

Key Words:acoustic emission; CFRP-CCFT column; process of damage; failure mode; safety evaluation

Abstract:Damage properties of carbon fiber-reinforced polymer (CFRP) confined circular concrete-filled steel tubular (CCFT) columns were analyzed through acoustic emission (AE) signals. AE characteristic parameters were obtained through axial compression tests. The severity of damage to CFRP-CCFT columns was estimated using the growing trend of AE accumulated energy as basis. The bearing capacity of CFRP-CCFT columns and AE accumulated energy improved as CFRP layers increased. The damage process was studied using a number of crucial AE parameters. The cracks' mode can be differentiated through the ratio of the rise time to the waveform amplitude and through average frequency analysis. With the use of intensity signal analysis, the damage process of the CFRP-CCFT columns can be classified into three levels that represent different degrees. Based on b-value analysis, the development of the obtained cracks can be defined. Thus, identifying an initial yielding and providing early warning is possible.

Pre One:环境侵蚀下钢-混凝土组合梁耐久性使用寿命分析

Next One:FRP-混凝土组合梁优化设计方法探讨