教授 博士生导师 硕士生导师
性别: 男
毕业院校: 大连理工大学
学位: 博士
所在单位: 化工学院
学科: 应用化学. 精细化工. 生物化工
办公地点: 西校区E-204
联系方式: xiaoyi@dlut.edu.cn 0411-84986251
电子邮箱: xiaoyi@dlut.edu.cn
开通时间: ..
最后更新时间: ..
点击次数:
论文类型: 期刊论文
发表时间: 2011-03-01
发表刊物: CHEMISTRY-A EUROPEAN JOURNAL
收录刊物: SCIE、EI、PubMed
卷号: 17
期号: 11
页面范围: 3179-3191
ISSN号: 0947-6539
关键字: donor-acceptor systems; fluorescence; FRET; mercury; sensors
摘要: We have connected a boron-dipyrromethene (BODIPY) donor to the 5' position of a tetramethylrhodamine (TMR) acceptor to form a high efficiency (over 99%) intramolecular fluorescence resonance energy transfer (FRET) cassette, BODIPY-rhodamine platform (BRP). While the good spectral overlap between the emission of BODIPY and the absorption of TMR was one favorable factor, another feature of this FRET system was the rigid and short biphenyl spacer that favored efficient through-bond energy transfer. More importantly, in this system, the 2'-carboxyl group of the rhodamine unit was preserved for the further modifications, which was as convenient as those carbonyl groups on the original rhodamines without connection to donors. For this reason, BRP is clearly differentiated from the previous ratiometric sensors based on donor rhodamine systems. To illustrate its value as a versatile platform, we introduced typical Hg2+ receptors into BRP, through convenient one-pot reactions on the 2'-carboxyl group, and successfully developed two ratiometric sensors, BRP-1 and BRP-2, with different spirocyclic receptors that recognized Hg2+ on different reaction mechanisms. Upon excitation at a single wavelength (488 nm), at which only BODIPY absorbed, both of the FRET sensors exhibited clear Hg2+-induced changes in the intensity ratio of the two strong emission bands of BODIPY and rhodamine. It should be noted that these ratiometric Hg2+ sensors exhibited excellent sensitivity and selectivity Hg2+, as well as pH insensitivity, which was similar to the corresponding (turn-on) rhodamine sensors. While both ratiometric probes were applicable for Hg2+ imaging in living cells, BRP-1 exhibited higher sensitivity and faster responses than BRP-2. Our investigation indicated that on a versatile platform, such as BRP, a large number of highly efficient ratiometric sensors for transition-metal ions could be conveniently developed.
上一条: Soluble Ladder Conjugated Polymer Composed of Perylenediimides and Thieno[3,2-b]thiophene (LCPT): A Highly Efficient Synthesis via Photocyclization with the Sunlight
下一条: Soluble Ladder Conjugated Polymer Composed of Perylenebisimides and Thieno[3,2-b]thiophene (LCPT): A Highly Efficient Synthesis via Photocyclization with the Sunlight