张吉礼

个人信息Personal Information

教授

博士生导师

硕士生导师

主要任职:Vice Dean of Graduate School

其他任职:建筑能源研究所所长

性别:男

毕业院校:哈尔滨建筑大学

学位:博士

所在单位:土木工程系

学科:供热、供燃气、通风及空调工程. 控制理论与控制工程. 建筑学

办公地点:大连市凌工路2号大连理工大学建设工程学院3号楼601室

联系方式:0411-84706260

电子邮箱:zjldlut@dlut.edu.cn

扫描关注

论文成果

当前位置: 中文主页 >> 科学研究 >> 论文成果

Experimental study on thermal performance of filled-type evacuated tube with U-tube

点击次数:

论文类型:期刊论文

发表时间:2012-06-01

发表刊物:HEAT AND MASS TRANSFER

收录刊物:SCIE、EI、Scopus

卷号:48

期号:6

页面范围:989-997

ISSN号:0947-7411

摘要:The filled-type evacuated tube with U-tube, in which the filled layer is used to transfer energy absorbed by working fluid in the U-tube, is proposed to eliminate the effect of thermal resistance between the absorber tube and copper fin of the conventional solar collector. In this paper, the thermal performance of the filled-type evacuated tube was researched by means of experimental study. In order to avoid the effect of some uncertain factors, the single collector tube was considered as investigated objective. The test setup of the thermal performance of the filled-type evacuated tube with U-tube was established. The results show that the filled-type evacuated tube with U-tube has a favorable thermal performance compared with the evacuated tube with copper fin. The heat efficiency of filled-type evacuated tube is higher than that of copper fin evacuated tube by 12%. The useful energy gain of filled-type evacuated tube is 22% higher than that of copper fin evacuated tube at the practical irradiance received (T) = 800 W/m(2) and flow rate (f) = 0.005 L/s. In addition, the exergy efficiency of the filled-type evacuated tube is higher than that of copper fin evacuated tube.