Abstract:In order to achieve water-power cogeneration,the last-stage exhaust
steam provided by condensing steam turbines under low vacuum operation
is utilized as thermal resources for the low-temperature multi-effect
distillation desalination system.Multi-stage heat-regenerative
mathematical model of power plant thermodynamic system is constructed by
matrix method.The off-design parameters under low vacuum operation are
calculated on the basis of Friuli Nagel formula.Then,the mathematical
model of low-temperature multi-effect distillation desalination system
is built through equivalent temperature difference method.It can be
concluded that within the selected temperature range of exhaust steam
there exist optimal temperature of exhaust steam and the number of
evaporators to make the fresh water cost lowest for different water
demands.The effect of the temperature difference between desalination
effects on the thermal economic performance of the water-power
cogeneration system is also discussed.