王友年
开通时间:..
最后更新时间:..
点击次数:
论文类型:期刊论文
发表时间:2016-08-01
发表刊物:PHYSICS OF PLASMAS
收录刊物:SCIE
卷号:23
期号:8
ISSN号:1070-664X
摘要:The harmonic probe technique may be used for the diagnostics of the plasma in insulative film deposition circumstances where the conventional Langmuir probe cannot work. In this study, we investigated the influence of the bias signal amplitude V-0 and frequency f of the harmonic probe on the diagnostic results. While the measured electron temperature T-e and ion density n(i) change little with f within the frequency range of 1-10 kHz, both of them show a considerable increase with V-0. The reasons for the results were analyzed, and based on the understanding, an improved harmonic probe technique was proposed. The validity of the improved technique was verified by comparing its results with those of a conventional Langmuir probe in Ar plasmas. The improved harmonic probe technique was applied in diagnostics of the plasma circumstance for microwave electron cyclotron resonance plasma enhanced radio frequency magnetron sputtering deposition of SiNx films. Published by AIP Publishing.