个人信息Personal Information
教授
博士生导师
硕士生导师
性别:男
毕业院校:大连理工大学
学位:博士
所在单位:机械工程学院
办公地点:机械学院(知方楼)7118室
联系方式:84708415
电子邮箱:zhangj@dlut.edu.cn
A New Calibration Method for Piezoelectric Testing System Based on Orthogonal Calibration Method
点击次数:
论文类型:期刊论文
发表时间:2019-09-01
发表刊物:JOURNAL OF DYNAMIC SYSTEMS MEASUREMENT AND CONTROL-TRANSACTIONS OF THE ASME
收录刊物:SCIE、EI
卷号:141
期号:9
ISSN号:0022-0434
关键字:variable angle loading device; incremental calibration method; piezoelectricity test; accuracy verification
摘要:The accuracy of piezoelectric test system has a direct influence on the accuracy of the vector force detection. Piezoelectric sensor parameters are obtained by calibration system calibrated through orthogonal calibration method. Accuracy of the application of field test lacks the corresponding theoretical basis, resulting in test system test accuracy is questioned. In this paper, piezoelectric force test system is used as the research object. In order to verify accuracy of piezoelectric test system through calibration of orthogonal calibration method, a variable angle deflection loading device was designed. An incremental calibration method for thrust test is put forward by applying vector force at different angles. Based on vector force coordinate transformation matrix, a deflection load test and analysis model are established. The vector force coordinates transformation matrix is used to calculate the experimental data obtained from the deviation angle test system, and the deviation of the vector force value is obtained. Finally, the accuracy, effectiveness and rationality of piezoelectric test system through the orthogonal calibration method are verified.