Hits:
Date of Publication:2014-01-01
Journal:防灾减灾工程学报
Volume:34
Issue:2
Page Number:173-179
ISSN No.:1672-2132
Abstract:Typical region closed to a station of Shanghai Metro Line 9was selected
as research background in this article.The correlative data are
collected based on the vibration test system of LabVIEW2010development
platform.The response,characteristics and propagation law of vibration
caused by train operation are analyzed based on the data collected from
the three directions of the ground points corresponding to the metro
tunnel central line as well as the vertical direction of the ground
points with various distances from the central line.The result shows
that the vertical vibration is the main form of ground vibration,and the
vibration amplitude tends to decrease with the distance from the central
line of the metro tunnel.There is an amplifier region at a distance of
15mfrom the central line.The sensitive frequency is in the range of
15~25Hz. The test area near the station of metro line 9has significant
representativeness for the research on environmental vibration under the
metro operation.No such research was reported on other metro lines.
Note:新增回溯数据