Current position: Home >> Scientific Research >> Paper Publications

Macro-micro modeling design in system-level and experiment for a micromixer

Release Time:2019-03-09  Hits:

Indexed by: Journal Article

Date of Publication: 2012-08-01

Journal: ANALYTICAL METHODS

Included Journals: Scopus、EI、SCIE

Volume: 4

Issue: 8

Page Number: 2334-2340

ISSN: 1759-9660

Abstract: A novel macro-micro modeling method has been presented for designing three-dimensional microfluidic devices in system-level. The macro model was used to solve mass transfer in simple modules of a microfluidic device, such as straight channels. The micro model was used to solve mass transfer in complicated modules of a microfluidic device, such as mixing channels. Then, the mass transfer in a microfluidic device was solved in system-level. The macro-micro modeling method was applied to a micromixer, and the concentration distribution in the micromixer can be evaluated. Compared with numerical simulation, the maximum relative deviation between macro-micro calculation and numerical simulation, results are 1.28% and the computational efficiency of macro-micro model was improved significantly with the numbers of straight channels increasing. The macromicro modeling method is proven to be an effective way for rapid design of microfluidic devices in system-level.

Prev One:The dual role of deposited microbead plug (DMBP): A blood filter and a conjugate reagent carrier toward point-of-care microfluidic immunoassay

Next One:微流控芯片设计方法研究进展