Laser-induced breakdown spectroscopy to monitor ion cyclotron range of frequency wall cleaning Li/D co-deposition in EAST tokamak

Hits:

Indexed by:期刊论文

Date of Publication:2017-05-01

Journal:FUSION ENGINEERING AND DESIGN

Included Journals:SCIE、EI

Volume:118

Page Number:98-103

ISSN No.:0920-3796

Key Words:Ambient gas; Magnetic field; LIBS; EAST; ICRF wall cleaning

Abstract:In this paper, laser-induced breakdown spectroscopy (LIBS) under magnetic field condition has been studied in laboratory and EAST tokamak. The experimental results reveal that in helium ambient gas, the magnetic field significantly enhances the LIBS signal intensity (similar to 3 times). The effect of time delay and laser fluence on the intensity of LIBS has been investigated for optimizing the signal to background ratio (S/B). The developed LIBS approach has been applied to monitor the cleaning performance of the first wall in the fusion device of EAST using the ion cyclotron range of frequency (ICRF). The experimental results demonstrate that the cleaning performance for Li/D co-deposition layer is effective under helium ambient gas. The removing rate of Li on the surface of W tile is faster than that on Mo tile in He-ICRF cleaning and the D/(D + H) ratio on Mo tile is higher by similar to 1.2 times than that on W tile. This work would indicate the feasibility of using LIBS to monitor the wall cleaning processes in EAST tokamak. (C) 2017 Elsevier B.V. All rights reserved.

Pre One:High sensitive and high temporal and spatial resolved image of reactive species in atmospheric pressure surface discharge reactor by laser induced fluorescence

Next One:Preliminary results of in situ laser-induced breakdown spectroscopy for the first wall diagnostics on EAST