location: Current position: Home >> Scientific Research >> Paper Publications

Research on corrosion monitoring for steel-reinforced concrete structures using fiber optic sensing technique

Hits:

Indexed by:会议论文

Date of Publication:2013-09-02

Included Journals:EI、Scopus

Page Number:2321-2325

Abstract:One novel kind of Brillouin corrosion sensor was proposed and tested in this paper. Distributing strain sensing ability was utilized to monitor the corrosion expansion which is the key reason for concrete corrosion deterioration. Strain sensitivity test was designed to obtain the strain coefficient. And then one kind of Brillouin corrosion sensor packaging structure was designed and developed. The test results show that there is good linear relationship between Brillouin frequency shift and strain, and also corrosion expansion strain can be monitored using corrosion sensor developed precisely. ? 2013 Taylor & Francis Group.

Pre One:基于分布式光纤传感技术的钢筋锈蚀监测

Next One:Experimental study on the corrosion of buried directly heating supply pipeline based on the BOTDA (R) technique