location: Current position: Home >> Scientific Research >> Paper Publications

双盘式渐开线测量仪测点位置调整方式

Hits:

Date of Publication:2022-10-10

Journal:光学精密工程

Affiliation of Author(s):机械工程学院

Issue:10

Page Number:1553-1557

ISSN No.:1004-924X

Abstract:The measurement error caused by the stylus position deviation in the double-disc involute measuring instrument was analyzed, and two methods, the test method and the error compensation method, for adjusting the stylus position accurately were introduced. In test method, with the angle of tooth profile being less than its real value when the stylus deviates the rails surface, the same involute tooth profile is measured repeatedly when the stylus is at different positions. The result shows that the stylus is in the best position when the angle of the tooth profile is maximal. In the error compensation method, the involute tooth profile is measured when the stylus is at two different positions over the rails, the results are compensated by attempting different values of the stylus deviation to get two results same, and the real deviation value can be obtained. The limited deviations of the two methods for adjusting the stylus position are ±0.010 mm and ±0.015 mm, which can meet demands for measuring level 1 (GB/T10 095.1-2 001) involute tooth profile.

Note:新增回溯数据

Pre One:双盘式渐开线测量仪精度分析

Next One:双盘式渐开线测量仪数据采集与控制系统的研制