location: Current position: Home >> Scientific Research >> Paper Publications

Double position sensitive detectors (PSDs) based measurement system of trajectory tracking of a moving target

Hits:

Indexed by:Journal Papers

Date of Publication:2017-01-01

Journal:ENGINEERING COMPUTATIONS

Included Journals:SCIE、EI、Scopus

Volume:34

Issue:3

Page Number:781-799

ISSN No.:0264-4401

Key Words:Measurement system; Moving target; PSD; Trajectory tracking

Abstract:Purpose - The purpose of this paper is to achieve the trajectory tracking measurement of a moving target based on double position sensitive detectors (PSDs).
   Design/methodology/approach - In this paper, first, a double PSD-based measurement system including hardware system and software system is built up. Then, the working principle is studied to calculate parameters, and calibration experience is conducted. Finally, this double PSD-based measurement system is used to test angular displacement and axial displacement on the tool magazine and automatic tool changer.
   Findings - In the experiment, the maximum position error of a space point based on double PSD measurement system is 0.8566 mm, and the average error is 0.4716 mm. These results show that the built double PSD-based measurement system of trajectory tracking of a moving target is reasonable.
   Originality/value - Combining the characteristics of the PSD and principles of binocular visual measurement, a non-contact three-dimensional measuring system based on double PSDs is developed. The designed double-based measurement system is quite suitable for measurement of a fast-changing illuminant or in the case that the tracking accuracy is not tight.

Pre One:Design of Double PSDs mounting plate on the tracing measurement system

Next One:Influence of feed per tooth on tool wear based on 3D finite element simulation in micro-milling of Inconel 718